Presenters
K.B. Nolen & S.G. Gibbs, NABLA Corp.
New methods for quantifying pump leakage are described. These methods extend the effectiveness of dynamometer analysis and can lessen the dependence on well tests in determining the degree of pump leakage. Actual examples are included to illustrate the techniques. A detailed description of traveling and standing valve leakage checks is also included.