Polished Rod Loads and Their Range of Stress

Presenters

A.A. Hardy, W.C. Norris Division, Dover Corp.

Practically all sucker rod breaks are fatigue failures. These breaks are brittle type fractures which occur at a stress much below either the ultimate strength or yield strength of the metal after a great number of stress reversal cycles. This type of failure is common to all metals and all kinds of metallic structures subjected to cyclic loading. To design a structure so that such failures cannot occur, we must determine the fatigue endurance limit of the metal we are using, then limit the working stresses to a safe value below this figure.